Twin Coil Cylinders - Add Heat and Plumb to your FavortiesTwin Coil Cylinders - Subscribe to Mailing ListCall Heat and Plumb about our great offers on Twin Coil CylindersSales for Twin Coil Cylinders are validated by 192.com Twin Coil Cylinders Page Shopping CartTwin Coil Cylinders Page Proceed to Checkout 
Discuss Twin Coil Cylinders in our discussion forum
Find Latest News Stories for Twin Coil CylindersFind a Qualified Installer for Twin Coil Cylinders
School's heating controls cut carbon - 13/05/2008 | 'Be aware of heating control requirements' - 13/05/2008 | Plumbers can report 'rogue customers' - 13/05/2008 | HSE gives back boiler warning - 12/05/2008 | Barnet schools to get renewable energy - 12/05/2008

Ariston Stainless Steel TWIN COIL Indirect Unvented Cylinder

-  Ref: HVA3060039/3829007

Ariston Stainless Steel TWIN COIL Indirect Unvented Cylinder Picture

   FEATURES
  • Quality stainless steel tank - 12 bar pressure tested


  • Environmentally sound and highly efficient thermal insulation


  • All plumbing and electrical connections within a 90° angle


  • Exclusive High Quality 'Orange Peel' Outer Finish


  • Twin Indirect Coils for Dual Heat Source Applications


  • Twin Immersion Heaters Supplied with Regulation Thermostat and Dual Pole Thermal Cut-Out


  • Cylinder Thermostats with External Regulation


  • Unique Coil Design allows full quantity of water to be heated


  • Factory fitted ½" T&P relief valve


  • Unvented control kit supplied with cylinder at no additional cost


  • Simple Installation


  • 25 Year Tank Guarantee (2 Year Guarantee on electrical components)
TECHNICAL INFO ITSI 210 ITSI 300
Capacity (Litres) 200 300
Weight Empty (kg) 44 60
Weight Full (kg) 244 360
Indirect Coil Rating (Top) 20.5 20.7
Indirect Coil Rating (bottom) 20.7 26.7
Coil Surface Area (Top) 0.75 0.75
Coil SurfaceArea (Bottom) 0.75 0.90
Indirect Reheat Time* (ΔT=50°C) 34 40
Voltage (V) 240 240
Power (kW) 3+3 3+3
Immersion Reheat Time** (ΔT=50°C) 240 350
Max Temperature (°C) 70 70
Heat Loss (kWh/24h) 60°C 240 2.85
Typical Application G H
*Based on Bottom Coil Only
**Based on Single Heating Element

** Typical Application Explained

G Domestic - 5 People + (Kitchen, 2 Bathrooms and Shower)
H Domestic - Above Average Household Use


DIMENSIONS ITSI 210 ITSI 300
a (mm) see diagram 940 1215
b (mm) see diagram 225 260
c (mm) see diagram 1475 1790
d (mm) see diagram 625 800
e (mm) see diagram 505 560
f (mm) see diagram 265 275
g (mm) see diagram 806 1116
h (mm) see diagram 1206 1516
i (mm) see diagram 1220 1556


25 Year Tank Guarantee

2 Year Electrical Guarantee

Delivery will take approximately 5 Working Days


From:   £1,062.75


      Descriptionexcl. VATinc. VAT



your guide to shops on the internet

This website is a registered member of the SafeShop Approval Program and meets the industry agreed requirements as a member business. Click to Verify.
Maestro LogoVisa Debit LogoMastercard LogoVisa LogoSolo LogoVisa Electron
Quality Twin Coil Cylinders | Buy Online with Confidence
Exclusive Twin Coil Cylinders News - Updated Daily
School's heating controls cut carbon 13/05/2008
Effective heating controls have been highlighted as a key element of a strategy to reduce costs and carbon emissions at a London school, it has emerged. Notre Dame Roman Catholic Girls' School undertook a series of projects to lower its environment impact after received a £10,000 donation, according to community website... (more)


'Be aware of heating control requirements' 13/05/2008
Homeowners should be aware of the regulations surrounding the heating systems, a heating and plumbing organisation has said. The Institute of Plumbing and Heating Engineering (IPHE) advised that people should seek help from professionals who have knowledge concerning the area, rather than attempting to install appliances such as radiators... (more)


Plumbers can report 'rogue customers' 13/05/2008
A West Sussex-based builder has set up a website for plumbers, heating engineers and other tradespeople to report 'rogue customers', it has emerged. Nigel Gray, who owns a glazing and conservatory firm, has given his fellow tradesman the chance to warn each about customers who refuse to pay for work to... (more)


HSE gives back boiler warning 12/05/2008
A warning over the solid-fuel back boilers has been issued after five incidents in five years were reported. The Health and Safety Executive (HSE) has issued a reminder to homeowners, tenants, landlords and heating professionals that redundant boiler can run the risk of exploding. In a statement, the HSE said:... (more)


Barnet schools to get renewable energy 12/05/2008
Hertfordshire primary schools are set to undergo a refurbishment programme which will introduce them to the benefits of renewable energy sources, it has been reported. As part of Barnet council's primary school capital investment programme (PSCIP), six primary schools will be refurbished with improvements built in to make them... (more)